Furnace Service in Los Gatos
Furnace Installation and Repair in Los Gatos, CA
Furnace repair, replacement and gas-to-heat-pump conversions for Los Gatos homeowners, from our San Jose shop. Below is what changes locally: the Town's online furnace permit, what its reach code does and doesn't say about furnaces, Title 24 duct testing and fuel rules, the Air District's zero-NOx standard, SVCE's furnace replacement rebate and the inspector's alarm and attic checks.
- Google 4.9130+ reviews
- Licensed C-36 · C-20 · ACSLB License #1101278
- 1-year labor warranty24/7 service since 1986

Furnace Services for Los Gatos Homes
Furnace Service in Los Gatos: What's Different
Most Los Gatos furnaces burn PG&E gas, and the rules around replacing one changed in 2026 with new state codes, a Town reach code and an Air District deadline ahead.
One online permit for the heating system
The Town's Online Permits System has a Residential Furnace Permit for repairing or replacing a furnace, air handler, compressor or boiler, or a complete heating and cooling system. Moving the furnace needs a drawing.
A failed furnace can be replaced with gas
The Town's reach code FAQ says a heat pump isn't required when a furnace breaks: the rule is triggered by installing or replacing an air conditioner, not a furnace.
A new furnace means a duct test
The State counts a gas furnace as an air handler. Replacing one triggers duct sealing by the installer and leakage testing by an ECC-Rater under the 2025 Energy Code.
The 2029 zero-NOx standard
Under the Air District's Rule 9-4, furnaces manufactured after January 1, 2029 must emit zero NOx. Nobody has to tear out a furnace that still works.
CO alarms before the final
Permitted work in an existing Los Gatos home triggers the smoke and carbon monoxide alarm retrofit: a CO alarm outside each sleeping area and on every level, installed before the final inspection.
Attic furnaces have their own checklist
The Town's attic furnace handout asks for an access opening of at least 22 by 30 inches, a 3-inch sediment trap and a condensate drain sloped 1/8 inch per foot to the outside.
A Homeowner’s Guide to Furnace Installation and Repair in Los Gatos
Gas from PG&E, power from SVCE
A Los Gatos gas furnace runs on gas that PG&E distributes; the Town’s 2021 notice on PG&E’s Main Street gas main replacement describes it as work to strengthen the gas distribution system in Los Gatos. Its blower, igniter and controls need electricity too, which Silicon Valley Clean Energy (SVCE) supplies to Los Gatos customers. If a heat pump conversion leaves you with no gas appliances, SVCE sends gas service changes, such as meter removal, to PG&E at 1-877-743-7782.
Permits for a furnace replacement
The Town requires a mechanical permit for every furnace installation or replacement. The Residential Furnace Permit on the Town’s Online Permits System covers:
- a furnace, air handler, compressor or boiler, repaired or replaced;
- a complete heating and air conditioning system replaced at once.
Permits are issued to the owner or a licensed contractor, and a contractor must hold a current Town business license. A relocated furnace needs a drawing; a conversion to a heat pump also needs an electrical permit for new circuits, and the Town’s Electrification Flyer confirms that replacing gas heating with electric equipment requires a permit. The Town adopted the 2025 California Mechanical Code without local changes.
For inspections, the Town asks for the request before 12 p.m. to get an inspection the next business day, and the inspector calls the afternoon before to confirm.
Title 24 rules on a changeout
The 2025 California Energy Code took effect on January 1, 2026. Its single-family compliance manual sets out what a furnace swap brings:
- Duct sealing: a gas furnace counts as an air handler, so replacing it triggers sealing and an ECC-Rater test of the connected ducts (the ECC program replaced HERS). Exceptions cover duct systems under 40 feet, ducts containing asbestos and ducts already sealed and certified.
- Fuel: prescriptively, the new heating unit must be gas or a heat pump. A gas furnace can’t be swapped for an electric wall heater; the only electric option is a heat pump.
- Efficiency: the furnace must meet minimum efficiency rules, which equipment sold in California already does.
- Thermostat: if the new system includes cooling and the thermostat isn’t a setback type, it must be replaced.
See duct repair and thermostats.
The Town’s reach code and your furnace
Ordinance 2380, adopted December 2, 2025, added two local rules for existing single-family homes. Neither is triggered by a furnace replacement alone:
- AC to heat pump: applies when the house gets a new or replacement air conditioner. Under its heat pump path, a gas furnace may remain as supplemental heat.
- Electric readiness: in remodels that need an electrical permit, it covers circuits and space for ranges, dryers and heat pump water heaters, not furnaces.
The Town’s FAQ is explicit that a heat pump isn’t required when a furnace breaks, and that repairs are unaffected. Its codes page makes the amendments effective “once approved by State Agencies,” and the Energy Commission’s local ordinance docket showed nothing from Los Gatos when we looked in October 2026, so our next call is to the Building Division ((408) 354-6876) before quoting.
The Air District’s zero-NOx standard
The Bay Area Air District’s Rule 9-4 has two dates for furnaces, both tied to when a unit is manufactured: an ultra-low NOx standard for fan-type central furnaces made after January 1, 2024, and zero NOx for any furnace made after January 1, 2029. According to the District, the only equipment on the market that meets zero NOx is electric, and working appliances don’t have to be replaced before they fail. If your furnace is near the end of its life, it’s worth pricing a heat pump or mini-split alongside a new furnace.
SVCE’s rebate for replacing a gas furnace
SVCE’s Home Rebates cover a heat pump that takes the place of a gas furnace or an electric resistance furnace in a house, ADU or building of up to four units. The conditions: reservation before installation, at least 16 SEER2, no single-stage units, the old furnace removed, no dual-fuel, and proof of permitting. Income-qualified customers get a larger rebate, and separate rebates cover prewiring and an in-home electrical service upgrade. An all-electric bonus requires removing every gas meter on the building. See HVAC rebates.
Alarms and attic furnaces
Permitted work sets off the Town’s smoke and CO alarm retrofit: a CO alarm outside each sleeping area, on every level, and in any bedroom with a gas appliance, generally hard-wired and interconnected, and alarms no more than 10 years past their manufacture date. If the inspector can’t get inside, the owner or contractor may sign the Town’s verification form.
For a furnace in the attic, the Town’s handout calls for an access opening of at least 22 by 30 inches (30 by 30 recommended), a 3-inch sediment trap near the appliance, a clean overflow pan and a condensate line sloped 1/8 inch per foot to the outside, never draining over a public right of way.
Sources
Town of Los Gatos: Building Division · Permit Applications · Apply for a Residential Furnace Permit · Inspection Request Information · Current Adopted Codes · Ordinance 2380 · Reach Code FAQ · Attic Furnace Installation Requirements · Smoke & Carbon Monoxide Alarm Retrofit Verification · Electrification Flyer · PG&E Gas Line Replacement Work (2021). California Energy Commission: 2025 Single-Family HVAC · 2025 Single-Family Residential Compliance Manual · Docket 25-BSTD-04. Bay Area Air District: Building Appliances Rule Implementation · Know the Facts. Silicon Valley Clean Energy: Home Rebates · Appliance Specifications (April 2026). Checked October 2026.
Furnace Prices in Los Gatos
Most repairs are quoted as a fixed price before we start, so you approve the cost before any work begins. These are typical prices for common jobs in our service area.
| Service | Typical price (USD) |
|---|---|
| Flame sensor | $150–$350 |
| Furnace igniter | $200–$450 |
| Pressure switch | $250–$500 |
| Inducer motor, gas valve or control board | $500–$1,500 |
| Blower motor | $400–$900 |
| Dual-fuel system (heat pump + furnace) | $10,000–$20,000 |
| Inspection feeWaived for service plan members | $59 |
Prices are installed, before any current special, and depend on access, materials and what we find.
In Los Gatos, a same-location furnace swap is permitted online, but a relocation needs a drawing, an attic unit must meet the Town's access and condensate rules, and the new air handler brings duct sealing and an ECC-Rater test, so leaky or long-neglected ducts can add work. Missing or outdated smoke and CO alarms also have to be fixed before the final.
Get a free estimate →Our new heat pump system has just been installed and we are very pleased with CPI and the new equipment. We are especially grateful for the knowledgeable and hard-working technician Bunhak, who worked throughout our recent heatwave to finish the job. We would highly recommend CPI for any HVAC installation or maintenance.
Linda G.Google review
Quality work, fair price, very responsive. Our go to company in Bay Area.
A. C.Google review
Prompt response, polite, knowledgeable. Good at explaining options and following through until solved.
Pauline M.Google review
Current Specials
Save on your visit. Mention the offer when you book.
- Any Plumbing Service$50 OFFGet Offer: Any Plumbing ServiceLimit 1 per household. Cannot be combined with other offers. Expires January 15, 2028. See details for Any Plumbing Service
- Sewer Line InspectionFREECamera inspectionGet Offer: Sewer Line InspectionLimit 1 per household. Cannot be combined with other offers. Expires January 15, 2028. See details for Sewer Line Inspection
- Water Heater Installation$250 OFFGet Offer: Water Heater InstallationLimit 1 per household. Cannot be combined with other offers. Expires January 15, 2028. See details for Water Heater Installation
- Second OpinionFREEAlready have a quote from another licensed plumber?Get Offer: Second OpinionFor customers with a quote from another licensed plumber. Expires January 15, 2028. See details for Second Opinion
- 12-Month Financing0%Interest for 12 monthsGet Offer: 12-Month FinancingThrough Synchrony, subject to financing approval. Expires January 15, 2028. See details for 12-Month Financing
- Seniors, Teachers & Healthcare Workers5% OFFSeniors 65+, teachers and healthcare workersGet Offer: Seniors, Teachers & Healthcare WorkersFor seniors 65+, teachers and healthcare workers. Expires January 15, 2028. See details for Seniors, Teachers & Healthcare Workers
Furnace Service in Los Gatos FAQs
Is a permit required for a new furnace in Los Gatos?
Yes. The Town requires a mechanical permit for any furnace installation or replacement. A licensed contractor or the owner can apply through the Online Permits System, where the Residential Furnace Permit covers a furnace, air handler, compressor or boiler, or a complete heating and air conditioning system; the Town estimates about 20 minutes to apply once registered. Relocating the furnace requires a drawing, and a contractor must hold a current Town business license. See furnace repair and replacement.
My furnace died. Does Los Gatos require a heat pump now?
No. The Town's Reach Code FAQ answers this directly: the policy relates to air conditioner installation, not furnace installations, so a broken gas furnace can be replaced with a new gas furnace. If the air conditioner is replaced at the same time, the Town's AC rule in Ordinance 2380 applies, and one of its two paths makes a heat pump the primary heat with the gas furnace kept as backup. Because the Town ties the start date to approval by State agencies, we check its status with the Building Division before quoting.
What does the Air District's 2029 furnace rule mean for me?
Under Rule 9-4, residential and commercial furnaces manufactured after January 1, 2029 must meet a zero-NOx limit, following an ultra-low NOx standard for fan-type central furnaces made after January 1, 2024. The District says the only commercially available equipment that meets zero-NOx today is electric, and that there is no mandate to remove or replace working appliances before they fail. A furnace replaced now can be gas; planning a heat pump for the next replacement keeps your options open. See heat pumps.
Does a new furnace mean a duct test?
Usually, yes. California's compliance manual treats a gas furnace as an air handler, and replacing an air handler or a heating coil triggers duct sealing and an ECC-Rater test: 10% total leakage or 7% to outside, or every accessible leak sealed and smoke-tested. Systems with less than 40 feet of duct, ducts with asbestos and ducts already sealed and certified by a rater are exempt. A furnace or ducts in the garage have a tighter 6% target. See duct repair and replacement.
Do I need carbon monoxide alarms for a furnace permit?
Yes. The Town applies California's smoke and CO alarm retrofit rules whenever permitted alterations or repairs are made to an existing home. A CO alarm goes outside each sleeping area and on every level, and inside any bedroom that contains a gas appliance. Alarms are generally hard-wired with battery backup and interconnected, unless that would mean opening walls or ceilings, and must be in place when the final inspection is requested.
What does SVCE require to rebate a heat pump that replaces my furnace?
Silicon Valley Clean Energy's Home Rebates require a reservation approved before installation, a heat pump rated 16 SEER2 or better (17 SEER, or any inverter heat pump, also qualifies), no single-stage units, and proof of a permit. The gas furnace should come out: a dual-fuel setup that keeps gas backup is not eligible. Ducted and ductless systems are both eligible, and an existing air conditioner isn't required. See SVCE heat pump rebates.
How much does furnace repair and installation cost in Los Gatos?
Most jobs are quoted as a fixed price before we start, so you know the cost up front. Typical prices: flame sensor $150–$350; furnace igniter $200–$450; pressure switch $250–$500; inducer motor, gas valve or control board $500–$1,500; blower motor $400–$900; dual-fuel system (heat pump + furnace) $10,000–$20,000. The inspection fee is $59, waived for service plan members.
Need furnace service in Los Gatos? Call us.
- CSLB License #1101278 (opens CSLB in a new tab): C-36 Plumbing · C-20 HVAC · A General Engineering
- 1-year labor warranty on our work
- BBB A+ Accredited Business (opens BBB in a new tab)
- Technicians trained and certified: NASSCO PACP, MACP and LACP · Rheem heat pump · Noritz Level 3 tankless · OSHA safety